What this screening formula includes
Area starts the estimate; ceiling, sun, and occupants adjust it.
The tool begins with 20 BTU per square foot, scales for ceiling height relative to eight feet, adjusts the envelope load for shade or strong sun, and adds 600 BTU for each occupant above two. It displays a ±10% range to show uncertainty.
What the quick estimate cannot see
Windows, insulation, leakage, climate, ducts, and internal gains matter.
Two rooms with the same floor area can have very different loads. Central systems also depend on duct condition, ventilation, latent moisture load, and room-by-room distribution.
Bigger is not automatically safer
Oversizing can shorten cycles and weaken moisture removal.
DOE guidance notes that oversized room air conditioners can use more energy and remove humidity poorly because of excessive on-off cycling. Choose within manufacturer sizing guidance and avoid rounding far upward “just in case.”
Use Manual J for installed equipment decisions
A licensed designer should verify a permanent system.
Use this tool to frame questions and compare room units. For central equipment replacement or major alterations, request a documented Manual J load calculation and confirm local permit and code requirements.
Screen a cooling load.
Estimate a room-equipment range. This is not a central-system sizing decision.
QUESTIONS THIS ANSWERS
Questions this answers
- How many BTUs do I need for a room?
- Why is square footage alone not enough to size central air conditioning?
Found something wrong? Report an error or read the corrections policy.